Airborne sound insulation calculator for walls and ceilings

How many decibels quieter can your wall and ceiling get?

Choose your wall or ceiling and a build-up of effective acoustic materials. We calculate the sound insulation in the lab and on site and show how many decibels the construction improves by.

  • For designers: Rw, C and Ctr, curve in 21 one-third octave bands
  • For homes and businesses: a clear result without expert knowledge
  • Free, no sign-up, instant result

Example calculation, lab Rw

11.5 cm brick partition with a 50 mm Potichu lining

Before: wall only
42dB
About 40 dB on site. Normal speech from the next room is audible and understandable.
After: Potichu system
67dB
About 51 dB on site. Loud speech is faintly audible but cannot be understood.
20406080125 Hz500 Hz2k Hzbeforeafter

Approximately 82 % lower perceived loudness

Approximate conversion of the improvement of the construction alone from Rw 42 to 67 dB. Not a guarantee of on-site results; flanking paths and bass can reduce the improvement.

What exactly we calculate

Sound insulation tells you how much noise a wall holds back

It is given in decibels as Rw. The higher the number, the less you hear from the next room.

Decibels are not linear. An improvement of 10 dB sounds roughly half as loud, 20 dB a quarter as loud. The gap between a wall with Rw 42 dB and one with 62 dB is therefore huge.

The lab value applies to the wall alone. On site, sound also travels through the floor, ceiling and side walls, so the result is lower. The calculator shows both values.

What you hear through the wall and how a neighbour’s speech sounds

  • up to 45 dBNormal speech from the next room is audible and understandable.
  • 45–50 dBNormal speech is barely audible. Loud speech can be partly understood.
  • 50–55 dBLoud speech is faintly audible but cannot be understood.
  • 55–60 dBLoud speech is barely audible. Music and TV are faintly audible.
  • 60–65 dBEveryday sounds are inaudible. From loud music mainly the bass gets through.
  • above 65 dBOnly very loud music is audible, mainly deep bass.

Why installation matters

Same boards, different result

A lining works like a spring: the air and infill in the cavity separate the heavy boards from the wall. Every rigid connection bypasses that spring.

On the same brick wall, the same build-up of Silio 16 and plasterboard gives three different results. A free-standing lining adds 25 dB, a frame screwed to the wall 21 dB and a direct lining without a cavity only 10 dB.

That is why the calculator takes both the fixing method and the quality of installation into account. Resilient strips, movement joints and a frame that never touches the wall matter as much as the material.

  • Free-standing lining67 dB
  • Frame rigidly fixed to the wall63 dB
  • Direct lining without a cavity52 dB
  • Wall only42 dB

RwCheck calculation for an 11.5 cm brick partition, a Silio 16 board and Diamant plasterboard, with a 50 mm cavity filled with Zino Acoustic. Lab Rw values.

What must be met

How many decibels the standard requires

Every country has its own requirements. They apply to the finished building and are proven by measurement. The calculator compares your result with the chosen standard and tells you how much is missing.

Wall betweenSlovakiaCzechiaAustria
rooms of the same flat40 dB40 dBno requirement
neighbouring flats54 dB53 dB55 dB
a flat and the stairwell or corridor52 dB52 dB55 dB
neighbouring detached or terraced houses60 dB57 dB60 dB
hotel rooms47 dB47 dB50 dB
standard offices37 dB37 dB50 dB

Slovakia to STN 73 0532-2:2024 and Czechia to ČSN 73 0532:2020, quantity R′w. Austria to OIB-Richtlinie 5:2023, quantity DnT,w. Other values apply to ceilings and doors; the calculator shows them for each situation.

Before and after examples

Four common situations

The values come from the same calculator. You can open and adjust each example in it.

Prefab concrete block

Neighbour behind a 14 cm concrete panel

Before: wall only
56dB
About 52 dB on site. Loud speech is faintly audible but cannot be understood.
After: Potichu system
73dB
About 57 dB on site. Loud speech is barely audible. Music and TV are faintly audible.

Free-standing lining, 50 mm profile, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.

Open in the calculator

Brick partition between rooms

11.5 cm hollow brick, plastered

Before: wall only
42dB
About 40 dB on site. Normal speech from the next room is audible and understandable.
After: Potichu system
67dB
About 51 dB on site. Loud speech is faintly audible but cannot be understood.

Free-standing lining, 50 mm profile, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.

Open in the calculator

The neighbour above

Porotherm 21 cm clay block floor, speech and music from above

Before: ceiling only
49dB
About 46 dB on site. Normal speech is barely audible. Loud speech can be partly understood.
After: Potichu system
68dB
About 52 dB on site. Loud speech is faintly audible but cannot be understood.

Ceiling on resilient hangers, 50 mm cavity, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.

Open in the calculator

A new partition instead of standard plasterboard

Same CW 75 studs, different boarding

Before: standard 2× plasterboard partition
54dB
About 52 dB on site. Loud speech is faintly audible but cannot be understood.
After: Potichu system
65dB
About 58 dB on site. Loud speech is barely audible. Music and TV are faintly audible.

Silio 16 and Diamant on both sides instead of two standard boards. The numbers are lab Rw; the description applies to a typical building with professional installation.

Open in the calculator

How it works

Three steps to a quieter room

  1. Choose a wall or ceiling

    Brick, aerated concrete, panel or concrete. The values come from manufacturers’ data sheets. For a new partition you need nothing.

  2. Choose the build-up

    Profile depth, fixing method, plasterboard and an optional bitumen layer. The cross-section is drawn to scale.

  3. See the result

    Sound insulation in the lab and on site, improvement in decibels, a plain description and installation warnings.

Who it is for

Design the silence before you start building

  • Flat and house ownersFind out what really helps against noise from neighbours.
  • Architects and designersQuick comparison of build-ups at the layout stage.
  • ContractorsA basis for your quote and an argument for correct installation.
  • Hotels, offices, surgeriesPartitions and linings where privacy matters.