Prefab concrete block
Neighbour behind a 14 cm concrete panel
Free-standing lining, 50 mm profile, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.
Open in the calculatorAirborne sound insulation calculator for walls and ceilings
Choose your wall or ceiling and a build-up of effective acoustic materials. We calculate the sound insulation in the lab and on site and show how many decibels the construction improves by.
Example calculation, lab Rw
11.5 cm brick partition with a 50 mm Potichu lining
Approximately 82 % lower perceived loudness
Approximate conversion of the improvement of the construction alone from Rw 42 to 67 dB. Not a guarantee of on-site results; flanking paths and bass can reduce the improvement.
What exactly we calculate
It is given in decibels as Rw. The higher the number, the less you hear from the next room.
Decibels are not linear. An improvement of 10 dB sounds roughly half as loud, 20 dB a quarter as loud. The gap between a wall with Rw 42 dB and one with 62 dB is therefore huge.
The lab value applies to the wall alone. On site, sound also travels through the floor, ceiling and side walls, so the result is lower. The calculator shows both values.
What you hear through the wall and how a neighbour’s speech sounds
Why installation matters
A lining works like a spring: the air and infill in the cavity separate the heavy boards from the wall. Every rigid connection bypasses that spring.
On the same brick wall, the same build-up of Silio 16 and plasterboard gives three different results. A free-standing lining adds 25 dB, a frame screwed to the wall 21 dB and a direct lining without a cavity only 10 dB.
That is why the calculator takes both the fixing method and the quality of installation into account. Resilient strips, movement joints and a frame that never touches the wall matter as much as the material.
RwCheck calculation for an 11.5 cm brick partition, a Silio 16 board and Diamant plasterboard, with a 50 mm cavity filled with Zino Acoustic. Lab Rw values.
What must be met
Every country has its own requirements. They apply to the finished building and are proven by measurement. The calculator compares your result with the chosen standard and tells you how much is missing.
| Wall between | Slovakia | Czechia | Austria |
|---|---|---|---|
| rooms of the same flat | 40 dB | 40 dB | no requirement |
| neighbouring flats | 54 dB | 53 dB | 55 dB |
| a flat and the stairwell or corridor | 52 dB | 52 dB | 55 dB |
| neighbouring detached or terraced houses | 60 dB | 57 dB | 60 dB |
| hotel rooms | 47 dB | 47 dB | 50 dB |
| standard offices | 37 dB | 37 dB | 50 dB |
Slovakia to STN 73 0532-2:2024 and Czechia to ČSN 73 0532:2020, quantity R′w. Austria to OIB-Richtlinie 5:2023, quantity DnT,w. Other values apply to ceilings and doors; the calculator shows them for each situation.
Before and after examples
The values come from the same calculator. You can open and adjust each example in it.
Neighbour behind a 14 cm concrete panel
Free-standing lining, 50 mm profile, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.
Open in the calculator11.5 cm hollow brick, plastered
Free-standing lining, 50 mm profile, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.
Open in the calculatorPorotherm 21 cm clay block floor, speech and music from above
Ceiling on resilient hangers, 50 mm cavity, Silio 16 and Diamant. The numbers are lab Rw; the description applies to a typical building with professional installation.
Open in the calculatorSame CW 75 studs, different boarding
Silio 16 and Diamant on both sides instead of two standard boards. The numbers are lab Rw; the description applies to a typical building with professional installation.
Open in the calculatorHow it works
Brick, aerated concrete, panel or concrete. The values come from manufacturers’ data sheets. For a new partition you need nothing.
Profile depth, fixing method, plasterboard and an optional bitumen layer. The cross-section is drawn to scale.
Sound insulation in the lab and on site, improvement in decibels, a plain description and installation warnings.
Who it is for