Airborne sound insulation calculator for constructions

Calculate your wall or ceiling

Choose what you are solving and set the build-up. The result updates after every change.

How much detail do you want to see?

You see the result in decibels, the comparison with the standard, the cross-section and warnings. That is enough to decide.

1What do you want to soundproof?

2What must be met

On site, this wall must reachDnT,w ≥ 55 dB

If the rooms are connected by a door, 50 dB is sufficient.

Austria rates DnT,w, converted from R′w for a room depth of 4.0 m. For rooms up to 10 m³ the requirements are 5 dB lower.

OIB-Richtlinie 5:2023, sections 2.3 to 2.5. Compliance is proven by on-site measurement.

3Construction build-up

Existing wall

Surface mass about 137 kg/m², Rw 42 dB (measured in a lab).

4Soundproofing: how we reduce the noise

Ruhig.at lining

The most effective option. The frame is held only by the floor and ceiling.
Depth of profile and Zino Acoustic infill

5Building and installation

6Result and compliance

Estimate in the finished building, R′w
49–53dB
Build-up alone in the lab, Rw
67dB

Loud speech is faintly audible but cannot be understood.

+25 dBthis is how much the wall with the lining beats the original wall. Laboratory comparison: The wall alone has Rw 42 dB. The lining adds 25 dB.

Approximately 82 % lower perceived loudness

Approximate conversion of the Rw improvement over the comparison construction, not a guarantee of on-site results. Flanking paths and bass can reduce the improvement.

About 3 dB short of the requirementThis simplified model cannot confirm compliance with the selected junctions. The entire room and transmission through adjoining structures need assessment. This does not mean no other solution exists.Requirement according to: OIB-Richtlinie 5:2023, sections 2.3 to 2.5.
Where the sound gets through
Directly through the wall3 %
Around, via the side walls81 %
Around, via floor and ceiling15 %

The result is limited by the side walls. Improving this wall further will hardly help on site. Try ticking linings on the side walls under Building and installation.

total thickness 228.5 mm
  • HELUZ 11,5, wall incl. plaster145.0 mm137.0 kg/m²
  • Air gap5.0 mm–
  • Metal profile 50 mm, Zino Acoustic infill50.0 mm2.0 kg/m²
  • Silio 16 sound insulation board16.0 mm21.7 kg/m²
  • Knauf Diamant 12.5 mm12.5 mm12.8 kg/m²
  • Total228.5 mm174 kg/m²

Materials and enquiry

Dimensions are taken from Building and installation.

MaterialQuantityNote
Metal profile 50 mm11.4 m²8 vertical studs, 8.8 m of track
Zino Acoustic fill11.4 m²
Silio 16 sound insulation board11.4 m²
Knauf Diamant 12.5 mm11.4 m²5 boards 1.2 × 2.0 m

Area 10.4 m², quantities include 10 % for offcuts. Approximate, openings not deducted.

What to watch out for

  • Fix the profiles only to the floor and ceiling over a resilient strip. Screws must not reach the wall.
  • The fire resistance of this build-up has not been tested. The Silio 16 board is combustible. Do not use it as a fire-separating element without assessment by a specialist.
How the calculator works and how accurate it is

Linings are based on measurements in an accredited lab on an 11.5 cm brick wall. The measured curves are converted to the chosen wall, boarding mass and cavity depth with a mass–spring–mass model (EN ISO 12354-1).

Partitions use a double-leaf wall model with sound bridges through the studs, calibrated to data from plasterboard system manufacturers.

The on-site value is an estimate: flanking transmission for the building type is added to the lab value and a loss for installation quality is deducted.

This is an approximate calculation, not a test report. The results cannot be used as declared properties of the construction or as a basis for fire assessment.

7PDF, save and quotation

PDF report

Save project

I want a quote

Contact details and message for the quotation.

Your inquiry will be saved. Email delivery is currently unavailable.

Calculation summary

On site · R′w
49–53 dB
In the lab · Rw
67 dB